The ability of RMC to work with a wide selection of matrix materials adds to the challenge of having a variety of curing systems available to meet the needs and requirements of customers.
RMC has the ability to react and respond to customer needs and employ the most efficient curing systems for each job. As production requirements grow and needs arise for dedicated systems they are designed and acquired or built for the specific requirements.

 

Autoclave System

Max. Allowable

Pressure
100 psi
Temperature
400 F
Capacity
6.0' dia. X 10.0' long

 

Duplex Oven

Max. Allowable

Vacuum
26 in/Hg
Temperature
500 F
Capacity
8' w X 8' h X 16' long

 

Both Systems utilize programmable controllers which can regulate temperature, pressure, and vacuum. An advanced Data Acquisition System records all pertinent information for document control purposes. The primary components being:

. Fluke Helios I - analog to digital converter.
. 100 channels - record time, temperature, pressure, and vacuum.
. 40 thermocouples - record accurate heat-ups.

Other systems such as controlled heat lamps and heated hoods are used when parts are cured in stages as required by the project.